  • AC/DC High Sensitivity Clamp-On Current Probe

    N7026A - Keysight Technologies

    The Keysight N7026A is a 150 MHz bandwidth, active current probe for InfiniiVision and Infiniium oscilloscopes. The probe features wide and flat bandwidth (DC-150 MHz), lower noise (<250 µArms), and wide input range (up to continuous 30 Arms or non-continuous 40 Apeak). This enables you to measure down to 1 mA/div, giving you a much more accurate view of your low-level signals.

  • AC / DC Current Probe, 100 KHz, 100 A

    1146B - Keysight Technologies

    The Keysight 1146B AC / DC probe provides accurate display and measurement of currents up to 100 A DC or peak AC / DC to 100 kHz without breaking the circuit. The 1146B AC / DC probe has hall-effect sensor technology to measure AC and DC signals. It is compatible with any Keysight oscilloscope with 0.2 to 0.5 V / div sensitivity and 1 MΩ BNC input.

  • Transmission Line Probes

    Teledyne LeCroy

    Transmission line probes are a special type of passive probe designed for use at very high frequencies. They replace the high impedance probe cable found in a traditional passive probe with a precision transmission line, with a characteristic impedance that matches the oscilloscope input (50 Ohm). This greatly reduces the input capacitance to a fraction of a picofarad, minimizing the loading of high frequency signals. A matching network at the tip increases the DC input resistance. While they have lower DC input resistance than a traditional passive probe (usually 500 Ohm) to 1kOhm), the input impedance of these probes remains nearly constant over their entire frequency range. A traditional /10 passive probe will have a 10 MOhm) input impedance at DC, however this impedance drops rapidly with frequency, passing below the input impedance of a transmission line probe at less than 100 MHz.

  • Near-Field Probes 100 kHz up to 50 MHz

    LF1 set - Langer EMV-Technik GmbH

    The LF1 near-field probe set consists of 4 shielded near-field probes used during the development process for emission measurement of longwave, medium wave, and shortwave frequencies on electronic devices. The probe heads of the LF1 set are designed for incremental detection of sources of electromagnetic interference on assemblies. First, the electromagnetic interference of the assembly is detected by the LF-R 400 probe from up to 10 cm. Then probes with higher resolution like the LF-B 3, LF-U 5 and LF-U 2.5 are used to more precisely detect any source of interference. The probe heads are designed for taking measurements at single pins and larger components. Near-field probes are small and handy. They have a current attenuating sheath and, therefore, are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. The H-field probes do not have an internal terminating resistance of 50 Ω.

  • Isolated Hall Effect Current Sensors

    Vektrex Electronic Systems

    Isolated Hall Effect current sensors provide accurate high bandwidth current sensing. Vektrex offers models to 320A. For use, the 50-ohm voltage output is connected directly to an oscilloscope or data acquisition system. VCS sensors are magnetically isolated like clamp-on oscilloscope probes. With secure cable attachment, repeatability is ensured.

  • Near Field Probes 30 MHz up to 3 GHz

    RF1 set - Langer EMV-Technik GmbH

    The RF1 near field probe set consists of 4 passive near field probes for making measurements in the development phase of E-field and magnetic field in the ranges of 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF1 set allow for measurements close to the electronic assemblies, e.g. on single IC pins, conducting paths, components and their connectors in order to localize interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.

  • Micro probes 1 MHz up to 6 GHz

    MFA 01 set - Langer EMV-Technik GmbH

    The micro probes are used to measure magnetic fields and they have a high resolution. They measure magnetic fields up to 6 GHz, e.g. at signal conductors (150µm), SMD components (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the Bias tee BT 706. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee BT 706 to a spectrum analyzer or an oscilloscope. Langer EMV-Technik GmbH includes correction lines in the delivery. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.

  • Micro probes 1 MHz up to 1 GHz

    MFA 02 set - Langer EMV-Technik GmbH

    The two in the set included micro probes are used to measure low-frequency magnetic fields up to 1 GHz, e.g. at signal conductors (150µm), SMD componets (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the BT 706 Bias tee. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee to a spectrum analyzer or an oscilloscope. The MFA 02 set delivery of Langer EMV-Technik GmbH includes correction lines. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.

  • Scope Probes

    3900 Series - Probe Master Inc.

    Now Probe Master offers a rugged, heavy duty oscilloscope probe at low prices. This probe features a snap-on rotating ground lead, and a heavy duty fixed tip. The switchable model allows for quick finger tip change between 1X, 10X and reference ground. The probe body is made of high impact ABS. Soft molded strain reliefs at all stress points assure long cable life. In short it has been designed to offer you high performance coupled with high quality at a low cost. Accessories include Sprung Hook, 6" Ground Lead and Trimmer Tool.

  • High Impedance Active Probes

    12C - Picoprobe

    A high speed, high input impedance active probe for measuring the internal node voltage of integrated circuits. The input is 1 megohm shunted by 0.1 pf and the rise/fall times are 0.8 ns. This instrument has full dc capability and can be used with any oscilloscope. The Model 12C was specially designed so that when used in conjunction with a high input impedance oscilloscope, signal attenuation is 10:1 and with a 50 Ohm input, signal attenuation is 20:1.

  • Portable Oscilloscope

    IkaScope WS200 - Ikalogic s.a.s.

    IkaScope is a new kind of instrument: It’s a full featured oscilloscope fitted inside a WiFi connected probe. IkaScope takes no extra space on your desk and follows you everywhere with a 1-week battery life. It connects to your computer, smartphone or tablet to display captured signals.

  • Active Probe

    Sonic - PMK Mess- und Kom­mu­nika­tion­stech­nik GmbH

    The Sonic® 4000 active probe offers best-in-class performance and is easy to use to make in-circuit measurements. The DC to >4GHz bandwidth, high input impedance, low noise and ±8V dynamic range make the Sonic 4000 the ideal probe for use with any oscilloscope or other 50Ω measurement system. The Sonic® 4000's ±12V input offset capability extends the probe's input voltage range.

  • Hook Test Clip

    PCM - Parrot Invent

    The PCM Parrot hook Test Clip model is a small size hook test clip with a length of 70 mm, including the metal tip and the button.Due to this smaller size it is aimed to be used for many applications as oscilloscope ground, spectrum analyzers, data lodgers multimeter test leads and probes.

  • Ultra Low Noise Preamp

    J2180A - PICOTEST Corp.

    The J2180A low noise preamplifier provides a fixed, AC coupled 20dB gain while converting a 1 MOhm input impedance to a 50 Ohm output impedance. With a 3dB bandwidth of 0.1Hz to 100MHz, the preamplifier improves the sensitivity of oscilloscopes, network analyzers and spectrum analyzers while reducing the effective noise floor and spurious response. The preamplifier can also serve as a low frequency DC blocker for a spectrum analyzer or you can use it to connect a high input impedance oscilloscope probe to 50 Ohm equipment.

  • Current Probe For Non-Intrusive Measurement Of AC, DC, And Waveform Currents

    CP 305 - GMC-I-PROSyS

    The CP 305 current probe has been designed for use with oscilloscopes respectively for accurate, non-intrusive measurement of AC, DC and complex waveform currents.Using advanced Hall Effect technology the CP 305 can measure currents accurately up to 450A peak over the frequency range of DC to 20 kHz.